Electromagnetic Heat Flowmeter
Diameter: DN25 ~ DN400
Nominal pressure: 0.6MPa/1.6MPa/4.0MPa
Lining material: Neoprene, Polyurethane Rubber, F4, F46
Electrode material: 316L, Ti, HB/HC, Ta, WC, Pt
Structure type: separated type, integrated type
MDM460
Used For
Liquid and Gas Differential Pressure Measurement, Marine, Aviation, Metrology, Scientific Research
Leave a MessageMDM460 differential pressure controller with local LED display, supports relay signal, analog or Modbus output. Maximum 5 controlling points.
MDM460 intelligent transmitting control could measure and control differential pressure accurately in rugged open environment. It can use RS485 netting and display local measure value, and provide analog standard signal or relay control signal. The product could be used for differential pressure measuring, transmitting, displaying and transforming of chemi-industry, metallurgy, ocean, aviation, measurement, science, etc.
Features
• RS485 semi-duplex communication interface to transmit data signal and do long-distance calibration; easy for netting and connecting with MODEM interface to achieve data wireless transmitting
• Using piezoresistive pressure/differential pressure sensor and digital correction compensation; high accuracy
• Strict testing and aging, stable performance; aluminum-alloy electronic housing; IP65 Protection
• Key setting and calibration, easy installation
• LED measuring value display and LCD status information display
• Max.5 relay to control
• Optional pressure port and standard output signal
Specifications
• Pressure range: 0~35kPa…3.5MPa
• Static pressure: ≤20MPa
• Output signal: analog 4~20mADC, 0~10/20mADC or 0/1~5VDC; digital RS485
• Accuracy: +0.25%FS(typ.); +0.5%FS (max.) including analog output’s lin.,rep. and hys.
• Zero temp.drift :+0.03%FS/℃ (≤100kPa), +0.02%FS/℃ (>100kPa)
• FS temp.drift: +0.03%FS/℃ (≤100kPa), +0.02%FS/℃ (>100kPa)
• Long-term stability: ≤+0.5%FS/year
• Power supply: 220VAC±15% or 220VDC or 24VDC
• Max. consumption: ≤3.5W
• Environment temp.: -10℃~60℃
• Media temp.: -10℃~80℃
• Acceleration: ≤3×9.81ms-2
• Storage temp.: -40℃~125℃
Image:
MDM460 differential pressure controller with local LED display, supports relay signal, analog or Modbus output. Maximum 5 controlling points.
MDM460 intelligent transmitting control could measure and control differential pressure accurately in rugged open environment. It can use RS485 netting and display local measure value, and provide analog standard signal or relay control signal. The product could be used for differential pressure measuring, transmitting, displaying and transforming of chemi-industry, metallurgy, ocean, aviation, measurement, science, etc.
Features
• RS485 semi-duplex communication interface to transmit data signal and do long-distance calibration; easy for netting and connecting with MODEM interface to achieve data wireless transmitting
• Using piezoresistive pressure/differential pressure sensor and digital correction compensation; high accuracy
• Strict testing and aging, stable performance; aluminum-alloy electronic housing; IP65 Protection
• Key setting and calibration, easy installation
• LED measuring value display and LCD status information display
• Max.5 relay to control
• Optional pressure port and standard output signal
Specifications
• Pressure range: 0~35kPa…3.5MPa
• Static pressure: ≤20MPa
• Output signal: analog 4~20mADC, 0~10/20mADC or 0/1~5VDC; digital RS485
• Accuracy: +0.25%FS(typ.); +0.5%FS (max.) including analog output’s lin.,rep. and hys.
• Zero temp.drift :+0.03%FS/℃ (≤100kPa), +0.02%FS/℃ (>100kPa)
• FS temp.drift: +0.03%FS/℃ (≤100kPa), +0.02%FS/℃ (>100kPa)
• Long-term stability: ≤+0.5%FS/year
• Power supply: 220VAC±15% or 220VDC or 24VDC
• Max. consumption: ≤3.5W
• Environment temp.: -10℃~60℃
• Media temp.: -10℃~80℃
• Acceleration: ≤3×9.81ms-2
• Storage temp.: -40℃~125℃
Diameter: DN25 ~ DN400
Nominal pressure: 0.6MPa/1.6MPa/4.0MPa
Lining material: Neoprene, Polyurethane Rubber, F4, F46
Electrode material: 316L, Ti, HB/HC, Ta, WC, Pt
Structure type: separated type, integrated type
Range: -1bar…0bar~0.35bar…35bar
Output signal: Digital I²C (pressure, temperature)
MDM7000-DGP Accuracy: ±0.075%,±0.1%,±0.2%URL
MDM7000-DAP Accuracy: ±0.1%、±0.2%URL
MDM7000-DGP Range:60mbar ~400bar
MDM7000-DAP Range: 0.4bar~100bar
Long-term stability: ±0.1%SPAN/5years
Maximum turndown ratio: 100:1
0bar~0.35bar...35bar
Accuracy: ±0.5%FS
4~20mA DC 0/1~5V DC 0~10/20mA DC
Ballast tank level monitoring achieves precise control of the ballast water system by using equipment such as electromagnetic flowmeters, level transmitters, and pressure transmitters to monitor data on inflow, tank liquid level, and pressure.
more info...In response to the national sustainable development strategy, enterprises typically install industrial wastewater treatment equipment, such as electromagnetic flowmeters and open channel flowmeters, to monitor and measure wastewater treatment and discharge.
more info...Real-time collection of reservoir water level, rainfall, and other information at dam monitoring points. Based on the changes in water level and the maximum capacity of the dam, calculations are made, and warnings and alarms are issued when the water level rises above the alert value.
more info...In HVAC duct systems, pressure measurement is crucial for maintaining optimal airflow. Pressure transmitters monitor air pressure to ensure efficient ventilation and proper air distribution. Accurate pressure data helps detect blockages, leaks, and maintain system balance, ensuring a comfortable and safe indoor environment.
more info...