Hygienic Pressure Transmitter
Pressure type: Gauge
Range: 0.1bar~30bar
Output signal: 4~20mA, 4~20mA+HART
Reference accuracy: ±0.2% upper range limit, maximum ±0.5% upper range limit
MW7000
Used For
Clean the measuring flange diaphragm.
Leave a MessageIntroduction
The flushing ring is a component of fluid piping systems installed between instrumentation and pipelines. Its primary function is to clean the measuring flange diaphragm, preventing errors caused by the attachment of liquid or impurities, thereby enhancing the accuracy and reliability of the transmitter. It facilitates fluid flushing, cleaning, and draining functions to ensure a favorable medium environment on the instrument diaphragm surface. The MW7000 flushing ring catalog includes flushing ring and flushing ring with mounted valve(s).
Functions
• Flushing ring
Equipped with open/closed flushing bores (with plug screws) to facilitate inlet and outlet of flushing media.
• Flushing ring with mounted valve
Equipped with open/closed flushing bores (with plug screws) to selectively allow or block internal media output.
The inlet side is fitted with a manual valve to regulate the flow of flushing media by adjusting the valve opening, to accommodate flushing requirements.
• Flushing ring with mounted valves
Equipped with manual valves at both inlet and outlet sides to regulate the flow of flushing media at both sides by adjusting the valve opening, to accommodate flushing requirements.
Image:
Introduction
The flushing ring is a component of fluid piping systems installed between instrumentation and pipelines. Its primary function is to clean the measuring flange diaphragm, preventing errors caused by the attachment of liquid or impurities, thereby enhancing the accuracy and reliability of the transmitter. It facilitates fluid flushing, cleaning, and draining functions to ensure a favorable medium environment on the instrument diaphragm surface. The MW7000 flushing ring catalog includes flushing ring and flushing ring with mounted valve(s).
Functions
• Flushing ring
Equipped with open/closed flushing bores (with plug screws) to facilitate inlet and outlet of flushing media.
• Flushing ring with mounted valve
Equipped with open/closed flushing bores (with plug screws) to selectively allow or block internal media output.
The inlet side is fitted with a manual valve to regulate the flow of flushing media by adjusting the valve opening, to accommodate flushing requirements.
• Flushing ring with mounted valves
Equipped with manual valves at both inlet and outlet sides to regulate the flow of flushing media at both sides by adjusting the valve opening, to accommodate flushing requirements.

Pressure type: Gauge
Range: 0.1bar~30bar
Output signal: 4~20mA, 4~20mA+HART
Reference accuracy: ±0.2% upper range limit, maximum ±0.5% upper range limit

Extremely low power consumption and auto sleep
Level and temperature measurement combination
Digital temperature compensation and non-linearity modulation

Range:-1bar...0~0.2bar…1000bar
Accuracy: ±0.25%FS (Typ.)
Power Supply: 1.5mADC

1, 2, 5, 10, 20, 50, 100, 200mH2O
Accuracy: ±0.25%FS (Typ.)
General Level Measurement

The roots flowmeter is the critical equipment in the system of urban gas gate station. As the basis of gas billing, roots flowmeter can accurately calculate the flow of natural gas. It is equipped with pressure transmitter with high accuracy, so as to guarantee the flow accuracy.
more info...
The micro-fused pressure transmitters can be used in hydrants to monitor the internal pressure of hydrants in real time, and send the data to the cloud platform for statistical analysis through wireless monitoring terminals and wireless networks. When an error occurs, it can locate the fault position and sends the alarm in time.
more info...
Real-time collection of reservoir water level, rainfall, and other information at dam monitoring points. Based on the changes in water level and the maximum capacity of the dam, calculations are made, and warnings and alarms are issued when the water level rises above the alert value.
more info...
Install instruments like electromagnetic flowmeters, temperature/pressure transmitters, flow controllers in the pressure pumps, water injection pipelines, and water injection wells to monitor the water injection volume, pressure, and level changes in real time so that the pressure and volume of the well-injected water can be controlled.
more info...